PM SENSOR (LASER)
(PAS-OUT-01) - For outdoor air quality monitoring applications. Range up to (0-31,000 µg/m³)
Request A Quote
Particulate Matter (PM) Sensoramazing features
Fan control for steady airflow
Built-in fault detection
Dust-proof duct design
Small size and easy to install
Excellent resistance to interference
Moisture-resistant circuit board
Multiple communication modes
Quick detection capability

PM SensorLaser Technology
Light scattering Method

PAS-OUT-01 is a Light-based designed Built for industries, digital laser sensor to measure particulate matter – dust particles. Since it comes with an Inbuilt laser and Light-based receiving module. Different than its contemporaries, PAS-OUT-01 is Set accurately for PM10 and PM2.5 Apart. Because it works on the principle of 90° light Spreading.
Range upto(0-31,000 µg/m³)
Seamless Connectivity
PM Sensor
Monitor and PM Sensor
WiFi connectivity to the monitor
Sensors Data transmission to cloud.
Displaying the Sensors data on mobile, laptop or TV.
The PM sensor has a compact design which allows the sensor to fit easily in any air quality monitor. Besides, anyone can integrate or change the sensor without requiring advanced technical knowledge. Also, the network access of the sensor is smooth as can directly transfer the data from the sensor to cloud for easy technology for users.
PM Sensors for outdoor and indoor
The PM Sensors has two options that meet the specific need of each environment so it offer optimal performance and better air quality monitoring.
PM Size Comparison

Particulate Matter or PM is a mixture of tiny particles or liquid droplets. And these also emits in the air from different sources. As a result, these particles can enter the human lungs and cause many harm to health.
PM1
Smaller than or 1µm
PM2.5
Smaller than or 2.5µm
PM10
Smaller than or 10µm
The Tiny Threats in the Air: Particulate Matter
Particulate Matter (PM) comes in various sizes as PM2.5 (particles smaller than 2.5 microns) and PM10 (particles smaller than 10 microns) the most common.
PM1
PM10
PM2.5
PM2.5
PM1
PM10
Know about each PM size
PM1
PM1 are the particles with a diameter of 1 micrometre or smaller which also includes nanoparticles and emissions from burning. Hence, these can easily enter the blood flow and cause health conditions.
PM2.5
PM2.5 refers to fine particles with a diameter of 2.5 micrometres or more smaller. Because of their tiny size, these are enough to enter deep into the lungs and result in severe health issues.
PM10
The particles in the air with a diameter of 10 micrometres or others smaller than PM10. It includes dust, pollen and mould and is large enough that mostly trapped in the nose or throat and results in allergies.
Particle Count
Lastly, these represent the total number of particles present in the air, without considering their individual sizes. Instead, it focuses on the overall particle load, including particles of various sizes.
Sources:
Vehicle Exhaust
Factory Emission
Construction sites
Wildfires
Dusty roads
Data Accuracy Level Comparison Chart With BAM

In a comprehensive comparative study evaluating the data accuracy of Prana Airs PM2.5 sensor against a high-end Beta Attenuation Monitoring (BAM) system.
Furthermore, the results demonstrated a high correlation between the two devices.
Happy to serve our clients
PM air quality sensor
applications
Construction Sites Covered by Prana Airs PM2.5 Sensor
The PM Sensor has been used across multiple construction sites to monitor high PM levels produced from various activities at these sites. As a result, it helps ensure real-time tracking of air quality and enables timely interventions when necessary.
500+
- Sites Covered
- Sites Covered
DPCC Guidelines
Outdoor PMCase Study
Laser PM sensor Case Study - I
Comparative Evaluation of New Low-Cost Particulate Matter Sensors
Study Brief : So, the paper involves our Prana Air device alongside other low-cost sensors for PM2.5 and PM10 measurements. For the results, they compared them to the standard Aeroqual Series-500. Since, their challenge with traditional devices was the high cost, heaviness, and frequent service needs, which limited usin in cities.

Note : Monitors update in every 30 seconds, moreover our PM sensors have a resolution of ±1.0 micrograms per cubic meter, and our NO2 sensors boast a resolution of ±1.0 ppb.

Find Full Study Here :https://pubmed.ncbi.nlm.nih.gov/37318651/
Laser PM sensor Case Study - II
Performance‐based protocol for selection of Affordable and easy to carry sensor for air quality measurement
Study Brief : In their research, they used our device in their Environmental Protection Sensors (EPS) assessment. So in this, they compared factory calibration data with reference monitors. Because, their challenge was reasonable cost with accuracy, sensitivity, and data management. In the result, Prana Air proved to be a reliable and affordable choice.
Find Full Study Here :https://pubmed.ncbi.nlm.nih.gov/37318651/
Health Impacts - Why it is important to measure particulate matter?

Asthma and Triggers

High risk of lung cancer

Respiratory infections

Lung diseases

Heart-related issues
Technical Specifications
Product Name:
PM Sensor
Rated voltage:
5V
Communication Port Level:
3.3 V
Dimensions L x W x H :
4.5 x 4.5 x 2 cm
Particle Size Resolution:
0.3 µm
Storage Temperature :
-20~85 C°
Working Temperature:
-20~70 C°
Working humidity:
0~99C%RH (No Moisture formation)
Rated current:
70mA
Mass concentration data resolution:
1 μg/m3
Outdoor Sensor Dimensions
Indoor Sensor Dimensions
Get in Touch
Please help us know what requirements you have. So, our team will contact you very soon.
Contact Info
Looking for Any Particulate Matter (PM) Sensor?
- Phone Number: (+91) 73918-73918
- Email Address: info@purelogic.in
- Office Location: 706, 7th Floor, Sec 10, Rohini, Delhi 85, India