Prana Air NH3 sensor is made with precision and fineness for both industrial-grade and consumer-grade safety monitoring. The sensor is based on electrochemical technology for highly toxic ammonia gas.

1

NH3 Sensor Introduction

The Prana Air NH3 sensor is designed with great accuracy and quality for both industrial and agricultural safety monitoring. It uses electrochemical technology to detect harmful ammonia (NH3) gas. This sensor is small, lightweight, and affordable, making it easy to use in different monitoring and safety systems. It is durable, lasts a long time, and can be used in a variety of settings, including farms, factories, refrigeration systems, and wastewater treatment plants.

  • 0.1 PPM Resolution
  • 50 PPM Range

Ammonia NH3 Sensor

Ammonia NH3 Sensor Variant A

The Prana Air NH3 sensor is designed with great accuracy and quality for both industrial and agricultural safety monitoring. It uses electrochemical technology to detect harmful ammonia (NH3) gas. This sensor is small, lightweight, and affordable, making it easy to use in different monitoring and safety systems. It is durable, lasts a long time, and can be used in a variety of settings, including farms, factories, refrigeration systems, and wastewater treatment plants.

  • 0.1 PPM Resolution
  • 50 PPM Range

Ammonia NH3 Sensor Variant B

Ammonia NH3 Sensor Variant B

Why Choose Ammonia NH3 Sensor Sensor?

  • Compact Icon

    Miniature Size

    Ultra-compact design for space-constrained applications

  • Durable Icon

    Weather Resistant

    Designed for outdoor environmental monitoring

  • Responsive Icon

    Real-time Detection

    Instant NH3 level monitoring

  • Energy Efficient Icon

    Battery Friendly

    Optimized for battery-powered devices

  • Calibrated Icon

    Factory Tested

    Each sensor individually tested and calibrated

  • RoHS Icon

    Eco-Friendly

    RoHS compliant and environmentally safe

NH3 Sensor Calibration Guide

NH3 Sensor Calibration Guide

Step-by-step calibration process to ensure accurate NH3 measurements in your application.

Advanced Sensing Technology

Electrochemical Detection

Learn More

Electrochemical Detection

Learn More

What is Ammonia (NH3)?

NH3 Pollution Sources

Ammonia (NHтВГ) is a colorless gas with a strong, pungent odor. It is highly toxic and can cause severe respiratory problems, skin burns, and eye damage. NHтВГ is lighter than air and can accumulate in enclosed spaces. The main sources of ammonia include agricultural activities (fertilizers, livestock), industrial processes (chemical manufacturing, refrigeration), wastewater treatment plants, cleaning products, and decomposing organic matter. Proper ventilation and NH3 detection are essential for preventing ammonia poisoning in agricultural and industrial environments.

Electrochemical Technology

Electrochemical Technology

The NH3 sensor uses electrochemical gas sensing technology to detect ammonia in the air. Our monitors use a special sensor to detect ammonia (NH3), a toxic gas commonly found in agricultural and industrial environments. This NH3 sensor works using a simple chemical process. It has two key parts called electrodes and a special material that connects them. When NH3 enters the sensor, a chemical reaction happens. This reaction creates a tiny electric current. The more NH3 in the air, the stronger the current. By measuring this current, our sensor tells us exactly how much NH3 is present. This helps in preventing ammonia exposure and keeping agricultural and industrial environments safer for workers.

NH3 Detection Module
  • NH3 Detection Module

    Buy Now
  • High-performance electrochemical cell with integrated electronics for precise NH3 measurement.

Applications of NH3 Sensor

Technical Specifications

  • Product Name

  • NH3 Sensor
  • Resolution

  • 0.1 PPM
  • Response Time

  • < 60 seconds
  • Operating Temperature

  • -20┬░C to +50┬░C
  • Operating Humidity

  • 15-90% RH
  • Measurement Range

  • 0-20 PPM
  • Repeatability

  • ┬▒3% of reading
  • Sensitivity

  • 0.1 PPM
  • Operating Voltage

  • 3.3V
  • Power Consumption

  • < 10mA
  • Product Name

  • NH3 Sensor
  • Resolution

  • 0.1 PPM
  • Response Time

  • < 60 seconds
  • Operating Temperature

  • -20┬░C to +50┬░C
  • Operating Humidity

  • 15-90% RH
  • Measurement Range

  • 0-20 PPM
  • Repeatability

  • ┬▒3% of reading
  • Sensitivity

  • 0.1 PPM
  • Operating Voltage

  • 3.3V
  • Power Consumption

  • < 10mA

Technical Support

Need help with NH3 sensor integration? Our engineers are here to assist you.

Contact Info

Looking for Any Indoor Air Quality Monitor?

  • Phone:
    (+91) 73918-73918

  • Email:
    info@purelogic.in

  • Office:
    706, 7th Floor, Sec 10, Rohini, Delhi 85, India

MonitorMonitorsMonitorsSensorSensorsSensorsBusinessBusineBusiness Solutions